SANDBOX TEST ONLY · No real payments or deliveries · 仅供沙盒测试,不扣真实款项、不配送商品
UNG Singapore
简体中文
UNG LAB

UNG test results

The UNG presentation summarises four tests by Korea Conformity Laboratories (KCL) using Staphylococcus aureus. The published percentages refer to the reported reduction in bacteria under each test condition.

Tests with bacteria present before treatment

Condition in the presentationReported reductionKCL report
One pass through the test system66.6%CT19-076176
One hour of circulation99.9%CT19-076179

Tests with bacteria introduced after water treatment

Condition in the presentationReported reductionKCL report
One pass, with the result assessed one hour after bacteria were introduced60.8%CT20-028785K
30 minutes of circulation, with the result assessed one hour after bacteria were introduced94.7%CT20-028784K

How to read the results

The presentation reports 0% reduction for the tap-water comparison in all four tests.

The tests used different conditions. The 99.9% figure was reported after one hour of circulation, while the single-pass test in the same group reported 66.6%. The two other tests measured the effect of treated water after bacteria were introduced. Their results should be read separately from the first two.

The presentation does not identify which retail model was tested. These are laboratory findings for one bacterial species under specific conditions. They do not establish the performance of either Singapore model during a normal shower or demonstrate a medical benefit.

Other water measurements

Hardness, cleaning index and conductivity figures are from the KATRI single-pass comparison summarised in UNG’s presentation. Surface-tension figures are from UNG’s Korean product page. These measurements describe water samples.

MeasureTap waterUNG treated water
Total hardness78.6 mg CaCO₃/L67.2 mg CaCO₃/L
Detergency index7.58.8
Surface tension70.6 mN/m70.4 mN/m
Conductivity249.6 µS/cm250.8 µS/cm

The presentation does not specify a unit for its detergency figures.

Source: UNG, Antibacterial Test presentation, product testing summary and KCL report references.

Additional results published on UNG’s Korean website

The wall-mounted product page presents the following water-safety and clinical-study summaries. The figures below are transcribed from UNG’s Korean product illustration.

Water-safety screening

UNG reports compliance or non-detection across 60 water-quality parameters. Examples shown include lead, chromium, iron, mercury, detergent, phenol, coliforms, general bacteria and fluoride.

Scalp and skin flaking

Measurement areaBefore useAfter two weeksAfter four weeksReported four-week reduction
Scalp4.944.323.6127%
Left cheek7.616.995.7324.7%

Sebum (oil) measurements

Measurement areaBefore useAfter two weeksAfter four weeksReported four-week reduction
Scalp110.0044.8624.6777.58%
Between the eyebrows143.6791.1070.1951.14%

Percentages are the improvements reported by UNG.

Hair-cuticle comparison

UNG presents microscopy images of hair before use, after two weeks and after four weeks, describing a smoother cuticle appearance.

Cleaning and surface tension

The Korean illustration shows a cleaning index of 7.5 before treatment and 8.8 after treatment, described as approximately 17% improvement. These values match the cleaning figures in the presentation above.

UNG’s Korean product illustration reports surface tension decreasing from 70.6 to 70.4 mN/m, a reduction of 0.2 mN/m.

Vitamin C model hydration claim

UNG’s Korean Vitamin C product listing advertises up to 225% improvement in moisturising performance.

Cart