UNG test results
The UNG presentation summarises four tests by Korea Conformity Laboratories (KCL) using Staphylococcus aureus. The published percentages refer to the reported reduction in bacteria under each test condition.
Tests with bacteria present before treatment
| Condition in the presentation | Reported reduction | KCL report |
|---|---|---|
| One pass through the test system | 66.6% | CT19-076176 |
| One hour of circulation | 99.9% | CT19-076179 |
Tests with bacteria introduced after water treatment
| Condition in the presentation | Reported reduction | KCL report |
|---|---|---|
| One pass, with the result assessed one hour after bacteria were introduced | 60.8% | CT20-028785K |
| 30 minutes of circulation, with the result assessed one hour after bacteria were introduced | 94.7% | CT20-028784K |
How to read the results
The presentation reports 0% reduction for the tap-water comparison in all four tests.
The tests used different conditions. The 99.9% figure was reported after one hour of circulation, while the single-pass test in the same group reported 66.6%. The two other tests measured the effect of treated water after bacteria were introduced. Their results should be read separately from the first two.
The presentation does not identify which retail model was tested. These are laboratory findings for one bacterial species under specific conditions. They do not establish the performance of either Singapore model during a normal shower or demonstrate a medical benefit.
Other water measurements
Hardness, cleaning index and conductivity figures are from the KATRI single-pass comparison summarised in UNG’s presentation. Surface-tension figures are from UNG’s Korean product page. These measurements describe water samples.
| Measure | Tap water | UNG treated water |
|---|---|---|
| Total hardness | 78.6 mg CaCO₃/L | 67.2 mg CaCO₃/L |
| Detergency index | 7.5 | 8.8 |
| Surface tension | 70.6 mN/m | 70.4 mN/m |
| Conductivity | 249.6 µS/cm | 250.8 µS/cm |
The presentation does not specify a unit for its detergency figures.
Source: UNG, Antibacterial Test presentation, product testing summary and KCL report references.
Additional results published on UNG’s Korean website
The wall-mounted product page presents the following water-safety and clinical-study summaries. The figures below are transcribed from UNG’s Korean product illustration.
Water-safety screening
UNG reports compliance or non-detection across 60 water-quality parameters. Examples shown include lead, chromium, iron, mercury, detergent, phenol, coliforms, general bacteria and fluoride.
Scalp and skin flaking
| Measurement area | Before use | After two weeks | After four weeks | Reported four-week reduction |
|---|---|---|---|---|
| Scalp | 4.94 | 4.32 | 3.61 | 27% |
| Left cheek | 7.61 | 6.99 | 5.73 | 24.7% |
Sebum (oil) measurements
| Measurement area | Before use | After two weeks | After four weeks | Reported four-week reduction |
|---|---|---|---|---|
| Scalp | 110.00 | 44.86 | 24.67 | 77.58% |
| Between the eyebrows | 143.67 | 91.10 | 70.19 | 51.14% |
Percentages are the improvements reported by UNG.
Hair-cuticle comparison
UNG presents microscopy images of hair before use, after two weeks and after four weeks, describing a smoother cuticle appearance.
Cleaning and surface tension
The Korean illustration shows a cleaning index of 7.5 before treatment and 8.8 after treatment, described as approximately 17% improvement. These values match the cleaning figures in the presentation above.
UNG’s Korean product illustration reports surface tension decreasing from 70.6 to 70.4 mN/m, a reduction of 0.2 mN/m.
Vitamin C model hydration claim
UNG’s Korean Vitamin C product listing advertises up to 225% improvement in moisturising performance.
